Three Rails, Two Eyes: A 100BASE-TX Transmitter Compliance Test at electronica 2026

• Thomas Hu

Field notes from electronica 2026, Munich.

Disclosure: I work for UNI-T (UNI-TREND Technology EU GmbH). This demo ran on our own stand. The readings are what the instruments showed during the show, not datasheet claims.

The second station on the UNI-T stand was labelled "Ethernet Compliance: 100/1000BASE-T, Tx Test, Compliance". On the main screen was an eye that does not look like a textbook eye: three rails and two stacked openings. That shape tells you immediately which PHY is being tested, and it is a good starting point for explaining what an Ethernet transmitter test actually checks.

UNI-T MSO8804HD 8 GHz 12-bit oscilloscope at electronica 2026 showing a three-level MLT-3 eye from a 100BASE-TX transmitter, with the CTS compliance analysis software running the UTP AOI template test
MSO8804HD (8 GHz, 20 GSa/s, 12-bit): three-level MLT-3 eye with the compliance software running the AOI template test. Photo: Thomas · @SignalByThomas

Three levels means 100BASE-TX

100BASE-TX sends 4B5B-coded data at 125 MBd using MLT-3 line coding: the output steps through +1, 0, −1, 0 and moves one step for every logical one. An eye diagram of MLT-3 therefore has three rails and two openings stacked vertically, exactly what was on screen. 1000BASE-T looks different again: PAM-5 on four pairs at once, with five levels. The fixture on the bench supports both PHYs, but the live test during my visit was the 100BASE-TX one.

The compliance software log made the sequence explicit:

  • 15:47:21 "Compliance test started"
  • 15:47:22 "UTP AOI template test started"
  • 15:47:51 "Suspend test" (a demo pause)

The AOI template is the Active Output Interface eye mask from the 100BASE-TX twisted-pair PMD specification. Every transition must stay out of the forbidden regions of the mask. It is the single most visual pass/fail test in the suite.

What a 100BASE-TX transmitter test checks

The mask is only one item. The standard transmitter tests also check, among other things:

  • Differential output amplitude, nominally 1 V peak (950–1050 mV), and the symmetry between positive and negative levels.
  • Rise and fall times of 3 to 5 ns, plus the symmetry between rise and fall.
  • Overshoot, limited to a few percent.
  • Transmit jitter, about 1.4 ns peak-to-peak with a scrambled idle pattern.

These limits are generous by modern standards, which is why the oscilloscope's bandwidth is not really the constraint. On this screen, channel 1 used an active differential probe, and the channel badge read 1 GHz and 10×, so the probe sets the channel bandwidth. A 1 GHz system has a 10–90 % rise time of roughly 0.35 ns. Added in quadrature to a 3 ns signal edge, that changes the measured rise time by well under 1 %. The 12-bit vertical resolution matters more here than bandwidth, because amplitude symmetry and overshoot are percentage measurements on a 1 V signal.

The fixture is half of the test

UNI-T GbE Ethernet compliance test fixture with sections for differential return loss, load and probe, common mode, disturbing signal injection and balun, with an RJ45 cable and active differential probe connected
The Ethernet test fixture: separate sections for return loss, load-and-probe, common mode, disturber injection and balun. Photo: Thomas · @SignalByThomas

The silkscreen on the fixture lists its sections: differential return loss, load and probe, common mode, a disturbing-signal section with DIST±, SCOPE± and DUT± connectors, and a balun. Each test needs a different electrical environment:

  • Load and probe: the DUT drives a defined 100 Ω differential load, and the scope probes across it. Template, amplitude, rise time and overshoot are measured here.
  • Return loss: measures how well the transmitter's output impedance matches 100 Ω across frequency. A poor match reflects energy back from the cable and degrades the link even when the eye looks clean.
  • Common mode: checks the common-mode output, which matters for emissions.
  • Disturbing signal: 1000BASE-T distortion tests inject a defined disturber, because in real operation all four pairs transmit and receive simultaneously.

The practical lesson is that "the eye passes" covers only one of several measurements. A transmitter can pass the template and still fail return loss.

Checklist for an Ethernet Tx compliance run

  • Identify the PHY from the eye: three levels for 100BASE-TX, five levels for 1000BASE-T.
  • Put the DUT into the right test mode or pattern (scrambled idle or a 1000BASE-T test mode) before measuring.
  • Use the fixture section matching the test; do not measure the template on the return-loss path.
  • Check that the probe, not the scope, sets the channel bandwidth, and that it is adequate (here more than enough).
  • Keep the trace at full vertical scale: amplitude symmetry and overshoot are percentage tests.
  • Run the full suite, not just the mask.

Takeaway

The three-rail eye on this station is MLT-3, so the live test was 100BASE-TX: the AOI template first, then amplitude, timing, overshoot and jitter. The oscilloscope's 8 GHz is not what makes this work. The probe sets a 1 GHz channel, which is ample for 3–5 ns edges. What matters is the right fixture section for each test, a DUT in the right test mode, and a full-scale 12-bit capture for the percentage measurements.

UNI-T Ethernet Compliance demo station at electronica 2026 with an MSO8804HD oscilloscope, a second oscilloscope and a large display showing the MLT-3 eye
The Ethernet Compliance station on the UNI-T stand. Photo: Thomas · @SignalByThomas

Notes: Observations are from the stand on 10 November 2026. Specification values are from the 100BASE-TX twisted-pair PMD requirements as commonly applied; check the current standard for your test plan. The rise-time estimate (0.35/BW) is my calculation. Pass/fail results were not visible in my photo.